Multi gas detector for Oxygen,Combustible gas.
[GOM-3A^GOM-3AL]
|
- Small/compact and lightweight with low power consumption
- A flick of a switch provides three different measurement modes
- With light & flow rate check function
- Measurement of combustible gases except methane
(for methane: GOM-3A)
- GOM-3AL provides ppm readings for combustible gases
|
| GOM-3A/GOM-3AL Specifications |
| Target gas |
Oxygen |
Combustible gas |
Combustible gas |
| GOM-3A |
 |
 |
N/A |
| GOM-3AL |
 |
N/A |
 |
| Measurement range |
0-25% |
0-100%LEL |
0-1000 ppm |
| Measurement principle |
Galvanic cell method |
Catalytic combustible combustion-type method |
| Sampling method |
Diaphragm pump |
| Display |
Analog metre (backlit) |
| Indicating Accuracy |
+/- 0.5%O2 |
5% of full scale |
| Alarm threshold |
18% |
20%LEL |
200 ppm |
| Alarm signal |
Short, intermittent sound and blinking alarm light |
Long intermittent sound and blinking alarm light |
| Power source |
Three size C manganese dry cell batteries for 4 hours of operation
(without alarm signal being emitted)
Three size C alkaline dry cell batteries for 8 hours of operation
(without alarm signal being emitted) |
| Dimensions |
150(W) x 70(D) x 110(H) (mm) |
| Weight |
1.2kg |
| Explosion proof |
Certified by Japan Ministry of Health, Labour and Welfare
(Class id3aG3 Certification No.T62340) |
Multiple gas detector for Oxygen, Combustible Gases,
Carbon monoxide / Hydrogen sulphide
[GOMC-3A/GOMH-3A]
|
- One unit for three type of gases
- Simultaneous measurement of oxygen, combustible gases
(non-methane), hydrogen sulphide and carbon monoxide
- Small / compact and lightweight
- Low power consumption design
- Light & flow rate check function
- Light & flow rate check function
|
| GOMC-3A/GOMH-3A Specifications |
| Target Gas |
Oxygen |
Combustible gas |
Hydrogen sulphide |
Carbon monoxide |
| GOMC-3A |
 |
 |
N/A |
 |
| GOMH-3A |
 |
 |
 |
N/A |
| Measurement range |
0-25%O2 |
0-100%LEL |
0-30 ppm |
0-300 ppm |
| Measurement principle |
Galvanic cell method |
Combustion contact |
Controlled potential electrolysis |
| Sampling method |
Diaphragm pump |
| Display |
Digital LCD (backlit) |
| Indicating accuracy |
+/- 0.5%O2 |
5% of full scale |
| Alarm threshold |
18% |
20%LEL |
10 ppm |
50 ppm |
| Alarm signal |
Short, intermittent sound and blinking alarm light |
| Power source |
Four size C dry cell batteries for approx. 4 hours of operation (without alarm signal being emitted) |
| Dimensions |
150(W) x 70(D) x 170(H) (mm) |
| Weight |
2kg |
Multiple gas detector for Oxygen, Combustible gas, Carbon monoxide, Hydrogen sulphide
[GOMHC-3A]
|
- One unit for four gases
- Simultaneous measurement of oxygen, combustible gases (non-methane), hydrogen sulphide and carbon monoxide
- Small/compact and lightweight
- Low power consumption design
- Light & flow rate check function
- Light & flow rate check function
|
| GOMHC-3A Specifications |
| Target Gas |
Oxygen |
Combustible Gas |
Hydrogen Sulphide |
Carbon Monoxide |
| GOMHC-3A |
 |
 |
 |
 |
| Measurement range |
0-25% |
0-100%LEL |
0-30 ppm |
0-300 ppm |
| Measurement principle |
Galvanic cell method |
Combustion contact method |
Controlled potential electrolysis |
| Sampling method |
Diaphragm pump |
| Display |
Digital LCD (backlit) |
| Indicating accuracy |
+/- 0.5%O2 |
5% of full scale |
| Alarm threshold |
18% |
20%LEL |
10 ppm |
50 ppm |
| Alarm signal |
Short, intermittent sound and blinking alarm light |
| Power source |
Four size C dry cell batteries for approx. 4 hours of operation (without alarm signal being emitted) |
| Dimensions |
150(W) x 70(D) x 170(H) (mm) |
| Weight |
2kg |
Multiple gas detector for Oxygen, Combustible gas, Hydrogen sulphide ,Carbon monoxide.
[GOMMH-3A/GOMMC-3A]
| GOMMH-3A/GOMMC-3A Specifications |
| Target Gas |
Oxygen |
Combustible gas |
Hydrogen sulphide |
Carbon monoxide |
| GOMMH-3A |
 |
 |
 |
N/A |
| GOMMC-3A |
 |
 |
N/A |
 |
| Measurement range |
0-25% |
0-100%LEL |
0-30 ppm |
0-300 ppm |
| Measurement principle |
Galvanic cell method |
Combustion contact method |
Controlled potential electrolysis |
| Sampling method |
Diaphragm pump |
| Display |
Digital LCD (backlit) |
| Indicating accuracy |
+/- 0.5%O2 |
5% of full scale |
| Alarm threshold |
18% |
20%LEL |
10 ppm |
50 ppm |
| Alarm signal |
Short, intermittent sound and blinking alarm light |
| Power source |
Four size C dry cell batteries for approx. 4 hours of operation (without alarm signal being emitted) |
| Dimensions |
150(W) x 70(D) x 170(H) (mm) |
| Weight |
2kg |