Methanol |
NO.111LL |
![]() |
| Measuring Range |
|
||
| Number of Pump Strokes |
|
||
| Correction Factor |
|
||
| Sampling Time | 2 minutes per pump stroke | ||
| Detecting Limit | 0.2 ppm (n=4) | ||
| Colour Change | Pale yellow → Pale bluish green | ||
| Reaction Principle | CH3OH + Cr6+ + H2SO4 → Cr3+ | ||
| Coefficient of Variation | 15% (for 2 to 5 ppm), 10% (for 5 to 20 ppm) | ||
| Shelf Life | 2 Years | ||
| Corrections for temperature & humidity | Temperature correction is necessary | ||
| Store the tubes at cool and dark place. | |||
| Substance | Concentration | Interference | Change colour by itself to |
| Alcohols | + | Pale bluish green | |
| Aromatic hydrocarbons | + | Pale bluish green |
| Calibration gas generation | Diffusion tube method |
| TLV-TWA | TLV-STEL | Explosive range |
| 200 ppm | 250 ppm | 6 to 36% |