Isopropyl alcohol |
NO.113 |
![]() |
| Measuring Range |
|
|||
| Number of Pump Strokes |
|
|||
| Correction Factor |
|
|||
| Sampling Time | 3 minutes per pump stroke | |||
| Detecting Limit | 0.004% (n=2) | |||
| Colour Change | Pink → Pale Blue | |||
| Reaction Principle | (CH3)2CHOH + Cr6+ + H2SO4 →Cr3+ | |||
| Coefficient of Variation | 15% (for 0.04 to 0.5 %), 10% (for 0.5 to 2.5 %) | |||
| Shelf Life | 3 Years | |||
| Corrections for temperature & humidity | Temperature correction is necessary | |||
| Store the tubes at cool and dark place. | ||||
| Substance | Concentration | Interference | Change colour by itself to |
| Other alcohols | + | Pale blue | |
| Carbon dioxide | No | No | |
| Carbon monoxide | No | No |
| Substance | Correction Factor | No. of pump strokes | Measuring Range |
| Propyl alcohol | 1 | 1 | 0.04 to 2.5 ppm |
| Calibration gas generation | Diffusion tube method |
| TLV-TWA | TLV-STEL | Explosive range |
| 200 ppm | 400 ppm | 2 to 12.7% |