Styrene |
NO.124 |
![]() |
| Measuring Range |
|
|||
| Number of Pump Strokes |
|
|||
| Correction Factor |
|
|||
| Sampling Time | 30 seconds per pump stroke | |||
| Detecting Limit | 1 ppm (n=2) | |||
| Colour Change | White → Yellow | |||
| Reaction Principle | C6H5CH:CH2+ H2S2O7 → Condensation Polymer | |||
| Coefficient of Variation | 15% (for 20 to 100 ppm), 10% (for 100 to 500 ppm) | |||
| Shelf Life | 3 Years | |||
| Corrections for temperature & humidity | Unnecessary | |||
| Store the tubes at cool and dark place. | ||||
| Substance | Concentration | Interference | Change colour by itself to |
| Alcohols | 0.5% | + (Bleaching) | No |
| Esters | 0.5% | + (Bleaching) | No |
| Ketones | 0.5% | + (Bleaching) | No |
| Calibration gas generation | Diffusion tube method |
| TLV-TWA | TLV-STEL | Explosive range |
| 20 ppm | 40 ppm | 1.1 to 6.1% |