Hydrogen sulphide |
NO.4HT |
![]() |
| Measuring Range |
|
|||
| Number of Pump Strokes |
|
|||
| Correction Factor |
|
|||
| Sampling Time | 1.5 minutes per pump stroke | |||
| Detecting Limit | 0.2% (n=2) | |||
| Colour Change | Pale Blue → Blackish Brown | |||
| Reaction Principle | H2S + CuSO4 → CuS + H2SO4 | |||
| Coefficient of Variation | 10% (for 2 to 6 %), 5% (for 6 to 20 %) | |||
| Shelf Life | 3 Years | |||
| Corrections for temperature & humidity | Unnecessary | |||
| Store the tubes at cool and dark place. | ||||
| Substance | Concentration | Interference | Change colour by itself to |
| sulphur dioxide | 5% | No | |
| Mercaptans | 10% | + | No |
| Calibration gas generation | High pressure gas cylinder method |
| TLV-TWA | TLV-STEL | Explosive range |
| 1 ppm | 5 ppm | 4.0 to 44% |