| Substance to be measured | Tube no. & name | Measuring range (ppm) |
Scale range (ppm) |
No. of tests per box |
Detector tube type | Notes | |
|---|---|---|---|---|---|---|---|
| Hydrogen | 30L | Hydrogen | 0.05-2.08% | (0.05)-0.8% | 5 | Short-term measurement | |
● Do not use this detector tube in environments where the Hydrogen concentration exceeds 2%.
● If used near substances with a low auto-ignition temperature, the detector tube may become an ignition source and cause an explosion.
● At Hydrogen concentrations of 1.5% or higher, the surface of the detector tube may become extremely hot, posing a risk of burns. Wear heat-resistant gloves and safety glasses/goggles when using this detector tube.