Calibration gas generation system

The Permeater is a gas generator for calibration purposes that utilises permeation and diffusion tubes to generate the calibration gas. When the permeation and diffusion tubes are set at a constant temperature, the weight of both the permeating and the evaporating diffusion gas will be respectively set at constant levels. In this manner, calibration gas is continuously generated by setting both tubes at a constant temperature and providing a constant flow of dilution gas such as air or nitrogen. This method is highly reliable because gas concentration levels are determined based on the dynamic weight loss obtained from measurements such as rate of permeation diffusion or evaporation diffusion as well as the quantity of dilution gas calculated by weight.

Product list

  • Calibration gas generation system

    Generating calibration gas with a permeation tube

    Permeation tube methyl bromideP-136-H

    Concentration range 0.5 - 23 ppm
    *As Permeation tubes have individual differences in permeation rates, the above concentration ranges may differ slightly from the actual range that can be controlled.

    Permeation tube methyl bromide P-136-H
  • Calibration gas generation system

    Generating calibration gas with a permeation tube

    Permeation tube methyl chlorideP-132-H

    Concentration range 1.6 - 77 ppm
    *As Permeation tubes have individual differences in permeation rates, the above concentration ranges may differ slightly from the actual range that can be controlled.

    Permeation tube methyl chloride P-132-H
  • Calibration gas generation system

    Generating calibration gas with a permeation tube

    Permeation tube methyl mercaptanP-71-5

    Concentration range 0.007 - 1.52 ppm
    *As Permeation tubes have individual differences in permeation rates, the above concentration ranges may differ slightly from the actual range that can be controlled.

    Permeation tube methyl mercaptan P-71-5
  • Calibration gas generation system

    Generating calibration gas with a permeation tube

    Permeation tube methyl mercaptanP-71-H

    Concentration range 0.16 - 11.4 ppm
    *As Permeation tubes have individual differences in permeation rates, the above concentration ranges may differ slightly from the actual range that can be controlled.

    Permeation tube methyl mercaptan P-71-H
  • Calibration gas generation system

    Generating calibration gas with a permeation tube

    Permeation tube methylamineP-182-H

    Concentration range 0.5 - 25.6 ppm
    *As Permeation tubes have individual differences in permeation rates, the above concentration ranges may differ slightly from the actual range that can be controlled.

    Permeation tube methylamine P-182-H
  • Calibration gas generation system

    Generating calibration gas with a permeation tube

    Permeation tube methylene chlorideP-138-H

    Concentration range 0.3 - 15.8 ppm
    *As Permeation tubes have individual differences in permeation rates, the above concentration ranges may differ slightly from the actual range that can be controlled.

    Permeation tube methylene chloride P-138-H
  • Calibration gas generation system

    Generating calibration gas with a permeation tube

    Permeation tube nitrogen dioxideP-9-1

    Concentration range 0.05 - 3.99 ppm
    *As Permeation tubes have individual differences in permeation rates, the above concentration ranges may differ slightly from the actual range that can be controlled.

    Permeation tube nitrogen dioxide P-9-1
  • Calibration gas generation system

    Generating calibration gas with a permeation tube

    Permeation tube nitrogen dioxideP-9-H

    Concentration range 1.8 - 133 ppm
    *As Permeation tubes have individual differences in permeation rates, the above concentration ranges may differ slightly from the actual range that can be controlled.

    Permeation tube nitrogen dioxide P-9-H
  • Calibration gas generation system

    Generating calibration gas with a permeation tube

    Permeation tube propaneP-100

    Concentration range 0.03 - 1.9 ppm
    *As Permeation tubes have individual differences in permeation rates, the above concentration ranges may differ slightly from the actual range that can be controlled.

    Permeation tube propane P-100
  • Calibration gas generation system

    Generating calibration gas with a permeation tube

    Permeation tube propylene oxideP-164-H

    Concentration range 0.3 - 15 ppm
    *As Permeation tubes have individual differences in permeation rates, the above concentration ranges may differ slightly from the actual range that can be controlled.

    Permeation tube propylene oxide P-164-H
  • Calibration gas generation system

    Generating calibration gas with a permeation tube

    Permeation tube StyreneP-124-H

    Concentration range 0.0045 - 0.22 ppm
    *As Permeation tubes have individual differences in permeation rates, the above concentration ranges may differ slightly from the actual range that can be controlled.

    Permeation tube Styrene P-124-H
  • Calibration gas generation system

    Generating calibration gas with a permeation tube

    Permeation tube sulphur dioxideP-5-5

    Concentration range 0.04 - 3.6 ppm
    *As Permeation tubes have individual differences in permeation rates, the above concentration ranges may differ slightly from the actual range that can be controlled.

    Permeation tube sulphur dioxide P-5-5
  • Calibration gas generation system

    Generating calibration gas with a permeation tube

    Permeation tube sulphur dioxideP-5

    Concentration range 0.1 - 7.2 ppm
    *As Permeation tubes have individual differences in permeation rates, the above concentration ranges may differ slightly from the actual range that can be controlled.

    Permeation tube sulphur dioxide P-5
  • Calibration gas generation system

    Generating calibration gas with a permeation tube

    Permeation tube sulphur dioxideP-5-H

    Concentration range 1.1 - 76.4 ppm
    *As Permeation tubes have individual differences in permeation rates, the above concentration ranges may differ slightly from the actual range that can be controlled.

    Permeation tube sulphur dioxide P-5-H
  • Calibration gas generation system

    Generating calibration gas with a permeation tube

    Permeation tube trimethylamineP-180-H

    Concentration range 0.06 - 3.1 ppm
    *As Permeation tubes have individual differences in permeation rates, the above concentration ranges may differ slightly from the actual range that can be controlled.

    Permeation tube trimethylamine P-180-H
  • Calibration gas generation system

    Generating calibration gas with a permeation tube

    Permeation tube vinyl chlorideP-131

    Concentration range 0.05 - 3.7 ppm
    *As Permeation tubes have individual differences in permeation rates, the above concentration ranges may differ slightly from the actual range that can be controlled.

    Permeation tube vinyl chloride P-131
  • Calibration gas generation system

    Generating calibration gas with a permeation tube

    Permeation tube vinyl chlorideP-131-H

    Concentration range 0.8 - 58 ppm
    *As Permeation tubes have individual differences in permeation rates, the above concentration ranges may differ slightly from the actual range that can be controlled.

    Permeation tube vinyl chloride P-131-H
  • Calibration gas generation system

    Generating calibration gas with a permeation tube

    Permeation tube vinylidene chlorideP-130-H

    Concentration range 0.16 - 8.2 ppm
    *As Permeation tubes have individual differences in permeation rates, the above concentration ranges may differ slightly from the actual range that can be controlled.

    Permeation tube vinylidene chloride P-130-H
  • Calibration gas generation system

    Generating calibration gas with a diffusion tube

    Diffusion tube3100

    Suitable for continuous generation of single component gases for calibration over sustained periods of time.

    Diffusion tube 3100
  • Calibration gas generation system

    Generating calibration gas with a diffusion tube

    Diffusion tube for multiple components3200

    Solvents such as thinner contain multiple components. Previous models permit the generation of single component gases for calibration purposes. However, a multiple component type diffusion tube enables the simultaneous generation of 4 types of gases for calibration. Employing this tube enhances analytical testing.

    Diffusion tube for multiple components 3200