Handy, compact type
The Gas sampling pump GV-100, pump accessories (3 rubber inlets and lubricant), as well as the instruction sheet are provided in a convenient shoulder bag.
GASTEC CORPORATION - For all types of gas and vapour
Optional accessories for easier, speedier and more accurate measurement
Handy, compact type
The Gas sampling pump GV-100, pump accessories (3 rubber inlets and lubricant), as well as the instruction sheet are provided in a convenient shoulder bag.
Shoulder-case type
The Gas sampling pump GV-100, pump accessories (3 rubber inlets and lubricant), as well as the instruction sheet are provided in a convenient shoulder bag.
Handy, compact type
Gas sampling pump kit with pump stroke counterGV-110S
The automatic sampling counter tells you how many pump strokes you already completed even though GASTEC tubes normally do not require so many pump strokes.
The Gas sampling pump GV-110, pump accessories (3 rubber inlets and lubricant), as well as the instruction sheet are provided in a convenient shoulder bag.
Safe storage of broken tips
The Tube tip holder doubles as a detector tube tip breaker and a storage receptacle for up to 260 broken tips, thereby preventing glass fragments from scattering.
Safety caps for tubes
Reusable rubber caps can be attached to the broken edges of the detector tubes as an extra precautionary safety measure. Blue caps can be used with the largest size detector tubes (outer diametre of 7mm) and pink ones with all other tubes. One (1) package contains 20 caps.
No.DTP-1-20(blue)
large-diametre tubes for tube nos. 1HH, 2HT, 2HH, 4HT, 31B (blue)
No.DTP-2-20(pink)
for all type of gas detector tubes except the above
Measuring in manholes, storage tanks, etc.
Extension hoses351A-5/351A-10/351A-30
Extension hoses are available to be attached to the inlet of the gas sampling pump (Model GV-100 or GV-110) and used for remote downward measurement in confined spaces, such as manholes, tanks, etc.
* For twin tube operation, order the Extension hose guard rubber (No.358) . When the extension hose tip needs to be replaced, order the Replacement extension hose guard rubber (No.359) .
351A-5 (for 5m long), 351A-10 (for 10m long), 351A-30 (for 30m long)
Accurate measuring of hot gases
Hot probe/Hot probe holder340/345A
The hot probe is a cooling device for measuring hot gases (60 to 600ºC / 140 to 1112 ºF) such as exhaust from vehicles and incinerators by cooling them down to normal temperatures. The stability of the device is enhanced when it is secured with the hot probe holder (No.345A)
Hot probe holder (Model 345A) can not be used with Twin-tubes and Oxygen tube No. 31B.
Horizontal and vertical measuring
Made of lightweight fiberglass and weighing only 590g, the extension sampling pole has a compact body (62.5 cm) for easy portability and can be extended to a maximum length of 2.8m.
Damage protection for twin tubes
The twin tube holder protects twin tubes from drop and damage or prevents injury to the user during a measurement.
One hand operation adapterGV-700
GV-700 can maintain a vacuum of 50mL or 100mL in the pump body. This allows the user to attach the appropriate tube to pump, and then in situations where it is necessary, to take the sample using one hand. In the body of the Adapter there is a small rod which can be moved in or out quite easily with one finger.
Kimitsu™Contaminated Vadose Zone Assessment technique
Contaminant distribution can be easily and accurately determined.
A hole is drilled in the ground with the boring rod, and the contaminants present in the gas in the hole are measured; by taking measurements at multiple points on a site the exact distribution of contaminants can be assessed.
Kimitsu™ Contaminated Vadose Zone Assessment technique
Extension pole for sub-surface sampling360
Contaminant distribution can be easily and accurately determined.
A hole is drilled in the ground with the boring rod, and the contaminants present in the gas in the hole are measured; by taking measurements at multiple points on a site the exact distribution of contaminants can be assessed.
The passive dositube can then be positioned in the worker's breathing zone where it can be attached with a holder and collar clip (separately available : Art.No.710) and the amount of individual exposure can be measured.
Determining gas flow direction in smoke
Break off both ends of the smoke tube and attach a rubber squeeze bulb to one end of the tube. When the bulb is squeezed, a chemical reaction produces white smoke. This smoke makes the air flow (in ventilation systems/ducts, etc.) visible. A single tube can be repeatedly used for about 50 tests.
Determining gas flow direction in smoke
This is a supplementary part for smoke tester set No. 500.
A single tube can be repeatedly used for about 50 tests.