GASTEC CORPORATION - For all types of gas and vapour

Gas sampling pump kit & accessories

Optional accessories for easier, speedier and more accurate measurement

Product list

  • Gas sampling pump kit & accessories Workplace atmospheres For shipping

    Handy, compact type

    Gas sampling pump kit with pump stroke counterGV-110S

    The automatic sampling counter tells you how many pump strokes you already completed even though GASTEC tubes normally do not require so many pump strokes.
    The Gas sampling pump GV-110, pump accessories (3 rubber inlets and lubricant), as well as the instruction sheet are provided in a convenient shoulder bag.

    Gas sampling pump kit  with pump stroke counter GV-110S
  • Gas sampling pump kit & accessories

    Safe storage of broken tips

    Tube tip holder722

    The Tube tip holder doubles as a detector tube tip breaker and a storage receptacle for up to 260 broken tips, thereby preventing glass fragments from scattering.

    Tube tip holder 722
  • Gas sampling pump kit & accessories

    Safety caps for tubes

    Rubber capsDTP-1-20/DTP-2-20

    Reusable rubber caps can be attached to the broken edges of the detector tubes as an extra precautionary safety measure. Blue caps can be used with the largest size detector tubes (outer diametre of 7mm) and pink ones with all other tubes. One (1) package contains 20 caps.

    No.DTP-1-20(blue)
    large-diametre tubes for tube nos. 1HH, 2HT, 2HH, 4HT, 31B (blue)
    No.DTP-2-20(pink)
    for all type of gas detector tubes except the above

    Rubber caps DTP-1-20/DTP-2-20
  • Gas sampling pump kit & accessories For shipping

    Measuring in manholes, storage tanks, etc.

    Extension hoses351A-5/351A-10/351A-30

    Extension hoses are available to be attached to the inlet of the gas sampling pump (Model GV-100 or GV-110) and used for remote downward measurement in confined spaces, such as manholes, tanks, etc.
    * For twin tube operation, order the Extension hose guard rubber (No.358) . When the extension hose tip needs to be replaced, order the Replacement extension hose guard rubber (No.359) .

    351A-5 (for 5m long), 351A-10 (for 10m long), 351A-30 (for 30m long)

    Extension hoses 351A-5/351A-10/351A-30
  • Gas sampling pump kit & accessories

    Accurate measuring of hot gases

    Hot probe/Hot probe holder340/345A

    The hot probe is a cooling device for measuring hot gases (60 to 600ºC / 140 to 1112 ºF) such as exhaust from vehicles and incinerators by cooling them down to normal temperatures. The stability of the device is enhanced when it is secured with the hot probe holder (No.345A)

    Hot probe holder (Model 345A) can not be used with Twin-tubes and Oxygen tube No. 31B.

    Hot probe/Hot probe holder 340/345A
  • Gas sampling pump kit & accessories

    Horizontal and vertical measuring

    Extension pole350BP-2

    Made of lightweight fiberglass and weighing only 590g, the extension sampling pole has a compact body (62.5 cm) for easy portability and can be extended to a maximum length of 2.8m.

    Extension pole 350BP-2
  • Gas sampling pump kit & accessories

    Damage protection for twin tubes

    Twin Tube HolderGV500

    The twin tube holder protects twin tubes from drop and damage or prevents injury to the user during a measurement.

    Twin Tube Holder GV500
  • Gas sampling pump kit & accessories

    One hand operation adapterGV-700

    GV-700 can maintain a vacuum of 50mL or 100mL in the pump body. This allows the user to attach the appropriate tube to pump, and then in situations where it is necessary, to take the sample using one hand. In the body of the Adapter there is a small rod which can be moved in or out quite easily with one finger.

    One hand operation adapter GV-700
  • Gas sampling pump kit & accessories Soil and water contamination

    Kimitsu™Contaminated Vadose Zone Assessment technique

    Boring (drill) rod361

    Contaminant distribution can be easily and accurately determined.
    A hole is drilled in the ground with the boring rod, and the contaminants present in the gas in the hole are measured; by taking measurements at multiple points on a site the exact distribution of contaminants can be assessed.

    Boring (drill) rod 361
  • Gas sampling pump kit & accessories Soil and water contamination

    Kimitsu™ Contaminated Vadose Zone Assessment technique

    Extension pole for sub-surface sampling360

    Contaminant distribution can be easily and accurately determined.
    A hole is drilled in the ground with the boring rod, and the contaminants present in the gas in the hole are measured; by taking measurements at multiple points on a site the exact distribution of contaminants can be assessed.

    Extension pole for sub-surface sampling 360
  • Gas sampling pump kit & accessories

    Determining gas flow direction in smoke

    Smoke tester kit500

    Break off both ends of the smoke tube and attach a rubber squeeze bulb to one end of the tube. When the bulb is squeezed, a chemical reaction produces white smoke. This smoke makes the air flow (in ventilation systems/ducts, etc.) visible. A single tube can be repeatedly used for about 50 tests.

    Smoke tester kit 500
  • Gas sampling pump kit & accessories

    Determining gas flow direction in smoke

    Smoke tube501

    This is a supplementary part for smoke tester set No. 500.
    A single tube can be repeatedly used for about 50 tests.

    Smoke tube 501