GASTEC CORPORATION - For all types of gas and vapour

Detector tube

Product list

  • Gas sampling pump kit & accessories

    One hand operation adapterGV-700

    GV-700 can maintain a vacuum of 50mL or 100mL in the pump body. This allows the user to attach the appropriate tube to pump, and then in situations where it is necessary, to take the sample using one hand. In the body of the Adapter there is a small rod which can be moved in or out quite easily with one finger.

    One hand operation adapter GV-700
  • Gas sampling pump kit & accessories Soil and water contamination

    Kimitsu™Contaminated Vadose Zone Assessment technique

    Boring (drill) rod361

    Contaminant distribution can be easily and accurately determined.
    A hole is drilled in the ground with the boring rod, and the contaminants present in the gas in the hole are measured; by taking measurements at multiple points on a site the exact distribution of contaminants can be assessed.

    Boring (drill) rod 361
  • Gas sampling pump kit & accessories Soil and water contamination

    Kimitsu™ Contaminated Vadose Zone Assessment technique

    Extension pole for sub-surface sampling360

    Contaminant distribution can be easily and accurately determined.
    A hole is drilled in the ground with the boring rod, and the contaminants present in the gas in the hole are measured; by taking measurements at multiple points on a site the exact distribution of contaminants can be assessed.

    Extension pole for sub-surface sampling 360
  • Gas sampling pump kit & accessories

    Determining gas flow direction in smoke

    Smoke tester kit500

    Break off both ends of the smoke tube and attach a rubber squeeze bulb to one end of the tube. When the bulb is squeezed, a chemical reaction produces white smoke. This smoke makes the air flow (in ventilation systems/ducts, etc.) visible. A single tube can be repeatedly used for about 50 tests.

    Smoke tester kit 500
  • Gas sampling pump kit & accessories

    Determining gas flow direction in smoke

    Smoke tube501

    This is a supplementary part for smoke tester set No. 500.
    A single tube can be repeatedly used for about 50 tests.

    Smoke tube 501
  • Detector tubes method for various application

    Quick impurity measurement for compressed breathing air

    Compressed Breathing Air Measurement KitCG-1

    Gastec CG-1 system can simply, quickly, and simultaneously measure 4 kinds of harmful contaminants (CO, CO2, Water vapour, and Oil mist)
    contained in compressed breathing air (cylinder or compressor).

    Compressed Breathing Air Measurement Kit CG-1
  • Detector tubes method for various application

    Pyrotec pyrolyzer840

    GASTEC developed the Pyrotec Pyrolyzer system to enable precise and easy detection of fluorochlorocarbon gases. It converts fluorochlorocarbon gases or halogenated hydrocarbons (using a process known as thermal cracking) into an easily detectable/measurable gas.

    Pyrotec pyrolyzer 840
  • Detector tubes method for various application

    Pyrotec pyrolyzer860

    GASTEC developed the Pyrotec Pyrolyzer system to enable precise and easy detection of Sulphuryl Fluoride. It converts Sulphuryl Fluoride (using process known as thermal cracking) into an easily measurable gas.

    Pyrotec pyrolyzer 860
  • Detector tubes method for various application

    Measurements inside a container

    Fumigation Probe380

    The GASTEC Fumigation Probe is connected to the Gas Detector Tube and inserted through the rubber seal of the closed container to measure residual fumigants.
    Currently, applicable tubes are limited.

    Fumigation Probe 380
  • Detector tubes method for various application For firefighting

    Quick, easy identification of toxic gases

    Toxic gas detection kitTG-1

    The primary step towards being able to prevent hazardous gas generation at the workplace, as part of occupational hygiene and pollution control, is to acquire accurate data regarding the emitted gas types and their concentration levels. Our hazardous gas detection kit consists of 12 detector tubes.

    Toxic gas detection kit TG-1
  • Detector tubes method for various application

    SO2,NO2 and O2 in smoke can be measured

    Flue gas measuring kitSG-1/SG-2

    The Environmental Agency of Japan recommends this kit as a means of exhaust gas detection. This kit is in use primarily at such smog generating sources as turbines and diesel engines. The GASTEC SG-1/SG-2 measuring system has been approved for three gases : sulphur dioxide, nitrogen oxide and oxygen.

    Flue gas measuring kit SG-1/SG-2
  • Detector tubes method for various application Soil and water contamination

    Waste water test kitWPT-132/WPT-133/WPT-135

    Enables concentrations of organic chlorinated solvents (e.g. tetrachloroethylene, trichloroethylene) present in wastewater to be easily measured.

    *We also have the Waste water test kit WP-132 / WP-133 / WP-135 which includes the Plastic syringe pump instead of the Gas sampling pump GV-100.

    Waste water test kit WPT-132/WPT-133/WPT-135
  • Detector tubes method for various application Soil and water contamination

    Waste water test kitWP-132/WP-133/WP-135

    Enables concentrations of organic chlorinated solvents (e.g. tetrachloroethylene, trichloroethylene) present in wastewater to be easily measured.

    *We also have the Waste water test kit WPT-132 / WPT-133 / WPT-135 which includes the Gas sampling pump GV-100 instead of the Plastic syringe pump.

    Waste water test kit WP-132/WP-133/WP-135
  • Detector tubes method for various application Soil and water contamination

    For measuring sulphides in waste water and sludge

    HYDROTEC-S330

    This kit enables quick measurement (approx. 10 min.) of sulphide in bodies of water or in waste water without any special equipment and skills. Take a sample with the gas generator tube, add sulphuric acid and simply measure the amount of hydrogen sulphide generated using the detector tube.

    HYDROTEC-S 330
  • Detector tubes method for various application Soil and water contamination

    Soil / Water

    Arsenic Detection Kit331

    This kit measures arsenic content in soil or in water. It takes about 15 minutes for the standard concentration of 0.01 to 0.5 mg/L in water. The kit requires no battery or power supply.

    Arsenic Detection Kit 331
  • Detector tubes method for various application Soil and water contamination

    Soil / Water

    Mercury Detection Kit332

    This kit measures mercury content in soil or water. It takes about 10 minutes for common concentrations between 0.005 and 0.04 mg/L in water. The kit requires no battery or power supply.

    Mercury Detection Kit 332