Determining gas flow direction in smoke
This is a supplementary part for smoke tester set No. 500.
A single tube can be repeatedly used for about 50 tests.
GASTEC CORPORATION - For all types of gas and vapour
Determining gas flow direction in smoke
This is a supplementary part for smoke tester set No. 500.
A single tube can be repeatedly used for about 50 tests.
Quick impurity measurement for compressed breathing air
Compressed Breathing Air Measurement KitCG-1
Gastec CG-1 system can simply, quickly, and simultaneously measure 4 kinds of harmful contaminants (CO, CO2, Water vapour, and Oil mist)
contained in compressed breathing air (cylinder or compressor).
GASTEC developed the Pyrotec Pyrolyzer system to enable precise and easy detection of fluorochlorocarbon gases. It converts fluorochlorocarbon gases or halogenated hydrocarbons (using a process known as thermal cracking) into an easily detectable/measurable gas.
GASTEC developed the Pyrotec Pyrolyzer system to enable precise and easy detection of Sulphuryl Fluoride. It converts Sulphuryl Fluoride (using process known as thermal cracking) into an easily measurable gas.
Measurements inside a container
The GASTEC Fumigation Probe is connected to the Gas Detector Tube and inserted through the rubber seal of the closed container to measure residual fumigants.
Currently, applicable tubes are limited.
Quick, easy identification of toxic gases
The primary step towards being able to prevent hazardous gas generation at the workplace, as part of occupational hygiene and pollution control, is to acquire accurate data regarding the emitted gas types and their concentration levels. Our hazardous gas detection kit consists of 12 detector tubes.
SO2,NO2 and O2 in smoke can be measured
Flue gas measuring kitSG-1/SG-2
The Environmental Agency of Japan recommends this kit as a means of exhaust gas detection. This kit is in use primarily at such smog generating sources as turbines and diesel engines. The GASTEC SG-1/SG-2 measuring system has been approved for three gases : sulphur dioxide, nitrogen oxide and oxygen.
Waste water test kitWPT-132/WPT-133/WPT-135
Enables concentrations of organic chlorinated solvents (e.g. tetrachloroethylene, trichloroethylene) present in wastewater to be easily measured.
*We also have the Waste water test kit WP-132 / WP-133 / WP-135 which includes the Plastic syringe pump instead of the Gas sampling pump GV-100.
Waste water test kitWP-132/WP-133/WP-135
Enables concentrations of organic chlorinated solvents (e.g. tetrachloroethylene, trichloroethylene) present in wastewater to be easily measured.
*We also have the Waste water test kit WPT-132 / WPT-133 / WPT-135 which includes the Gas sampling pump GV-100 instead of the Plastic syringe pump.
For measuring sulphides in waste water and sludge
This kit enables quick measurement (approx. 10 min.) of sulphide in bodies of water or in waste water without any special equipment and skills. Take a sample with the gas generator tube, add sulphuric acid and simply measure the amount of hydrogen sulphide generated using the detector tube.
Soil / Water
This kit measures arsenic content in soil or in water. It takes about 15 minutes for the standard concentration of 0.01 to 0.5 mg/L in water. The kit requires no battery or power supply.
Soil / Water
This kit measures mercury content in soil or water. It takes about 10 minutes for common concentrations between 0.005 and 0.04 mg/L in water. The kit requires no battery or power supply.
Injection-Type Gas Measurement System (Carbon dioxide)610
In No.610 System, samples are injected into detector tubes by using a syringe in order to measure gases in very high concentrations or slow in chemical reactions.
Injection-Type Gas Measurement System (Propane)600
In No.600 System, samples are injected into detector tubes by using a syringe in order to measure gases in very high concentrations or slow in chemical reactions.
Automatic Air Sampling PumpGSP-501FT
Compact, lightweight, and reliable automatic air sampling pump for GASTEC detector tubes and sorbent tubes.
Automatic Air Sampling PumpGSP-400FT
Flow volume of 50-1000mL/min can be set.
Activated charcoal tube251S-20
The activated charcoal tube is used in work environments where organic-solvent vapour is collected. Generally the activated charcoal tube is suited for detection of almost all organic solvents of low polarity .
2 layers,Charging quantity : 100/50mg
Activated charcoal tube251S2-20
The activated charcoal tube is used in work environments where organic-solvent vapour is collected. Generally the activated charcoal tube is suited for detection of almost all organic solvents of low polarity .
1 layers,Charging quantity : 150mg
The activated charcoal tube is used in work environments where organic-solvent vapour is collected. Generally the activated charcoal tube is suited for detection of almost all organic solvents of low polarity .
2 layers,Charging quantity : 100/50mg
Activated charcoal tube258A-20
The activated charcoal tube is used in work environments where organic-solvent vapour is collected. Generally the activated charcoal tube is suited for detection of almost all organic solvents of low polarity .
2 layers,Charging quantity : 400/200mg